JN Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Neurophysiol 39: 844-851, 1976;
0022-3077/76 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Clamann, H. P.
Right arrow Articles by Henneman, E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Clamann, H. P.
Right arrow Articles by Henneman, E.

Journal of Neurophysiology, Vol 39, Issue 4 844-851, Copyright © 1976 by APS


ARTICLES

Electrical measurement of axon diameter and its use in relating motoneuron size to critical firing level

H. P. Clamann and E. Henneman

1. Action potentials of single plantaris motoneurons were recorded monophasically from fine ventral root filaments. A resistor was placed in shunt across the recording electrodes and its value was varied until the size of the action potentials was reduced by one-half. At this point the resistance of the filament was taken to be equal to that of the shunt, and the quotient of action-potential amplitude divided by filament resistance was proportional to the axonal action current. 2. The measurement of axonal action currents depends on the assumption that the filament-electrode system obeys Ohm's law. Tests were performed which validated this assumption. It was then shown that the axonal action currents varied as the square of conduction velocity over the range of alpha and gamma motoneurons. 3. A direct correlation was established between the critical firing levels of motoneurons and the sizes of the impulses in their axons after the recorded sizes had been normalized in accordance with the resistances of the ventral root filaments in which they were located. Since both the CFL and axonal diameter were related to impulse size, they were related to each other (Fig. 6). 4. Evidence is cited justifying the conclusion that the dimater of a motor axon is directly related to the size of its soma. Thus, it may be inferred that the critical firing level of a motoneuron is a function of its size.


This article has been cited by other articles:


Home page
J. Neurophysiol.Home page
D. J. Simons, G. E. Carvell, H. T. Kyriazi, and R. M. Bruno
Thalamocortical Conduction Times and Stimulus-Evoked Responses in the Rat Whisker-to-Barrel System
J Neurophysiol, November 1, 2007; 98(5): 2842 - 2847.
[Abstract] [Full Text] [PDF]


Home page
J. Neurophysiol.Home page
H. Fukami and R. M. Bradley
Biophysical and Morphological Properties of Parasympathetic Neurons Controling the Parotid and von Ebner Salivary Glands in Rats
J Neurophysiol, February 1, 2005; 93(2): 678 - 686.
[Abstract] [Full Text] [PDF]


Home page
ScienceHome page
H. Desnedt and E Gidaux
Spinal motoneuron recruitment in man: rank deordering with direction but not with speed of voluntary movement
Science, November 20, 1981; 214(4523): 933 - 936.
[Abstract] [PDF]


Home page
ScienceHome page
J. Hoffer, M. O'Donovan, C. Pratt, and G. Loeb
Discharge patterns of hindlimb motoneurons during normal cat locomotion
Science, July 24, 1981; 213(4506): 466 - 467.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online