JN Watch the video to learn how APS reaches out to developing nations.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Neurophysiol 61: 208-217, 1989;
0022-3077/89 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Binder-Macleod, S. A.
Right arrow Articles by Clamann, H. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Binder-Macleod, S. A.
Right arrow Articles by Clamann, H. P.

Journal of Neurophysiology, Vol 61, Issue 1 208-217, Copyright © 1989 by APS


ARTICLES

Force output of cat motor units stimulated with trains of linearly varying frequency

S. A. Binder-Macleod and H. P. Clamann
Department of Physiology, Medical College of Virginia, Richmond 23298.

1. A relation between stimulation frequency and muscle force is usually determined with stimulus trains of constant frequency and described as a single-valued sigmoid curve. This relationship fails to explain a number of features of rate coding. 2. Single motor units were isolated in medial gastrocnemius or soleus muscles of cats deeply anesthetized with pentobarbital sodium. Motor units were classified as fast or slow. Each unit was stimulated with a train whose frequency varied linearly from less than 3 pulses per second (pps) to 20% above the unit's fusion frequency and back to about 3 pps with a period of 5 s. 3. All motor units showed a marked hysteresis during frequency-varying stimulation. A greater force was produced when frequency was decreasing than when it was increasing. The force output of each unit remained nearly maximal as stimulus frequency declined from its maximum to about one-half of the unit's fusion frequency; force rapidly declined with further decreases in frequency. The force-frequency relation could change with each trial as frequency increased but was highly reproducible when frequency decreased. This suggested a strategy by which central nervous system (CNS) control could maximize the force at any discharge rate and produce a predictable force-frequency relation. 4. Posttetanic potentiation, motor unit slowing, and a preload which causes a motor unit to operate on the negatively sloping portion of the length-tension curve may each contribute to the observed hysteresis under certain circumstances. None can explain why hysteresis was consistently seen in all motor units. A time-dependent rate of tension development and decay together with a catchlike property can account for all of the properties of hysteresis and appeared to be the primary cause of hysteresis in fully potentiated motor units.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
R. D. Maladen, R. Perumal, A. S. Wexler, and S. A. Binder-Macleod
Effects of activation pattern on nonisometric human skeletal muscle performance
J Appl Physiol, May 1, 2007; 102(5): 1985 - 1991.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
D. W. Russ, K. Vandenborne, and S. A. Binder-Macleod
Factors in fatigue during intermittent electrical stimulation of human skeletal muscle
J Appl Physiol, August 1, 2002; 93(2): 469 - 478.
[Abstract] [Full Text] [PDF]


Home page
J. Neurophysiol.Home page
M. Gorassini, J. F. Yang, M. Siu, and D. J. Bennett
Intrinsic Activation of Human Motoneurons: Possible Contribution to Motor Unit Excitation
J Neurophysiol, April 1, 2002; 87(4): 1850 - 1858.
[Abstract] [Full Text] [PDF]


Home page
J. Neurophysiol.Home page
M. Gorassini, J. F. Yang, M. Siu, and D. J. Bennett
Intrinsic Activation of Human Motoneurons: Reduction of Motor Unit Recruitment Thresholds by Repeated Contractions
J Neurophysiol, April 1, 2002; 87(4): 1859 - 1866.
[Abstract] [Full Text] [PDF]


Home page
Physiol. Rev.Home page
S. C. Gandevia
Spinal and Supraspinal Factors in Human Muscle Fatigue
Physiol Rev, October 1, 2001; 81(4): 1725 - 1789.
[Abstract] [Full Text] [PDF]


Home page
J. Neurosci.Home page
D. F. Collins, D. Burke, and S. C. Gandevia
Large Involuntary Forces Consistent with Plateau-Like Behavior of Human Motoneurons
J. Neurosci., June 1, 2001; 21(11): 4059 - 4065.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
S. C. K. Lee, C. N. Becker, and S. A. Binder-Macleod
Activation of human quadriceps femoris muscle during dynamic contractions: effects of load on fatigue
J Appl Physiol, September 1, 2000; 89(3): 926 - 936.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
S. C. K. Lee and S. A. Binder-Macleod
Effects of activation frequency on dynamic performance of human fresh and fatigued muscles
J Appl Physiol, June 1, 2000; 88(6): 2166 - 2175.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
E. van Lunteren and C. B. Sankey
Catchlike property of rat diaphragm: subsequent train frequency effects in variable-train stimulation
J Appl Physiol, February 1, 2000; 88(2): 586 - 598.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
S. C. K. Lee, C. N. Becker, and S. A. Binder-Macleod
Catchlike-inducing train activation of human muscle during isotonic contractions: burst modulation
J Appl Physiol, November 1, 1999; 87(5): 1758 - 1767.
[Abstract] [Full Text] [PDF]


Home page
ptjournalHome page
S. C. Lee, M. L Gerdom, and S. A Binder-Macleod
Effects of Length on the Catchlike Property of Human Quadriceps Femoris Muscle
Physical Therapy, August 1, 1999; 79(8): 738 - 748.
[Abstract] [Full Text] [PDF]


Home page
J. Neurosci.Home page
S. J. Goldberg, M. A. Meredith, and M. S. Shall
Extraocular Motor Unit and Whole-Muscle Responses in the Lateral Rectus Muscle of the Squirrel Monkey
J. Neurosci., December 15, 1998; 18(24): 10629 - 10639.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
J. Ding, S. A. Binder-Macleod, and A. S. Wexler
Two-step, predictive, isometric force model tested on data from human and rat muscles
J Appl Physiol, December 1, 1998; 85(6): 2176 - 2189.
[Abstract] [Full Text] [PDF]


Home page
J. Neurophysiol.Home page
S. A. Binder-Macleod, S. C. K. Lee, A. D. Fritz, and L. J. Kucharski
New Look at Force-Frequency Relationship of Human Skeletal Muscle: Effects of Fatigue
J Neurophysiol, April 1, 1998; 79(4): 1858 - 1868.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online