JN Ad Instruments
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Neurophysiol 65: 1509-1516, 1991;
0022-3077/91 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (75)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Thomas, C. K.
Right arrow Articles by Johansson, R. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Thomas, C. K.
Right arrow Articles by Johansson, R. S.

Journal of Neurophysiology, Vol 65, Issue 6 1509-1516, Copyright © 1991 by APS


ARTICLES

Force-frequency relationships of human thenar motor units

C. K. Thomas, B. Bigland-Richie and R. S. Johansson
Department of Physiology, University of Umea, Sweden.

1. Force-frequency relationships were examined in 30 human thenar single motor units. The technique of intraneural stimulation was used to stimulate the motor axon in the median nerve proximal to the elbow with a tungsten microelectrode. 2. The stimulation consisted of either single shocks or trains of pulses (1 or 2 s duration) at constant rates varying between 5 and 100 Hz. To control various mechanical artifacts, the stimuli were delivered after electronically resetting the force baseline, and the stimuli were phased to the pulse pressure wave. Thumb flexion and abduction force components were recorded and the magnitude and direction of the resultant force calculated. Electromyographic responses (EMG) were recorded from both the proximal and distal thenar muscle surfaces. 3. For all units, twitch force began to fuse between 5 and 8 Hz and maximum tetanic force was achieved between 30 and 100 Hz. Half-maximum tetanic force was produced at 12 +/- 4 (SD) Hz, as assessed by interpolation using the nearly linear force-frequency relationship between 8 and 30 Hz (on logarithmic frequency coordinates). 4. For the majority of units (n = 19), the strongest force changes in response to variations in stimulation frequency occurred between 5 and 10 Hz (sensitivity 6 +/- 1 mN/Hz). Fewer units showed highest force-frequency sensitivity between 8 and 15 Hz (n = 7; 4 +/- 3 mN/Hz) or 10 and 20 Hz (n = 4; 5 +/- 2 mN/Hz).(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
BrainHome page
C. K. Thomas, C. K. Hager-Ross, and C. S. Klein
Effects of baclofen on motor units paralysed by chronic cervical spinal cord injury
Brain, November 10, 2009; (2009) awp285v1.
[Abstract] [Full Text] [PDF]


Home page
J. Neurophysiol.Home page
D. Farina and D. Falla
Discharge Rate of Sternohyoid Motor Units Activated With Surface EMG Feedback
J Neurophysiol, February 1, 2009; 101(2): 624 - 632.
[Abstract] [Full Text] [PDF]


Home page
J. Neurophysiol.Home page
J. J. Kutch, A. D. Kuo, A. M. Bloch, and W. Z. Rymer
Endpoint Force Fluctuations Reveal Flexible Rather Than Synergistic Patterns of Muscle Cooperation
J Neurophysiol, November 1, 2008; 100(5): 2455 - 2471.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
K. N. Bishop, J. R. McClung, S. J. Goldberg, and M. S. Shall
Anatomic and physiological characteristics of the ferret lateral rectus muscle and abducens nucleus
J Appl Physiol, November 1, 2007; 103(5): 1706 - 1714.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
J. Lim, R. B. Gorman, J. P. Saboisky, S. C. Gandevia, and J. E. Butler
Optimal electrode placement for noninvasive electrical stimulation of human abdominal muscles
J Appl Physiol, April 1, 2007; 102(4): 1612 - 1617.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Regul. Integr. Comp. Physiol.Home page
L. M. Romer, H. C. Haverkamp, M. Amann, A. T. Lovering, D. F. Pegelow, and J. A. Dempsey
Effect of acute severe hypoxia on peripheral fatigue and endurance capacity in healthy humans
Am J Physiol Regulatory Integrative Comp Physiol, January 1, 2007; 292(1): R598 - R606.
[Abstract] [Full Text] [PDF]


Home page
J. Neurophysiol.Home page
C. K. Hager-Ross, C. S. Klein, and C. K. Thomas
Twitch and Tetanic Properties of Human Thenar Motor Units Paralyzed by Chronic Spinal Cord Injury
J Neurophysiol, July 1, 2006; 96(1): 165 - 174.
[Abstract] [Full Text] [PDF]


Home page
J. Physiol.Home page
C. S. Klein, C. K. Hager-Ross, and C. K. Thomas
Fatigue properties of human thenar motor units paralysed by chronic spinal cord injury
J. Physiol., May 15, 2006; 573(1): 161 - 171.
[Abstract] [Full Text] [PDF]


Home page
J. Neurophysiol.Home page
C. K. Thomas, R. S. Johansson, and B. Bigland-Ritchie
EMG Changes in Human Thenar Motor Units With Force Potentiation and Fatigue
J Neurophysiol, March 1, 2006; 95(3): 1518 - 1526.
[Abstract] [Full Text] [PDF]


Home page
J. Neurophysiol.Home page
C. T. Moritz, B. K. Barry, M. A. Pascoe, and R. M. Enoka
Discharge Rate Variability Influences the Variation in Force Fluctuations Across the Working Range of a Hand Muscle
J Neurophysiol, May 1, 2005; 93(5): 2449 - 2459.
[Abstract] [Full Text] [PDF]


Home page
J. Neurophysiol.Home page
P. Zhou and W. Z. Rymer
Factors Governing the Form of the Relation Between Muscle Force and the EMG: A Simulation Study
J Neurophysiol, November 1, 2004; 92(5): 2878 - 2886.
[Abstract] [Full Text] [PDF]


Home page
J. Neurophysiol.Home page
A. M. Taylor, E. A. Christou, and R. M. Enoka
Multiple Features of Motor-Unit Activity Influence Force Fluctuations During Isometric Contractions
J Neurophysiol, August 1, 2003; 90(2): 1350 - 1361.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
M. Shinohara, S. Li, N. Kang, V. M. Zatsiorsky, and M. L. Latash
Effects of age and gender on finger coordination in MVC and submaximal force-matching tasks
J Appl Physiol, January 1, 2003; 94(1): 259 - 270.
[Abstract] [Full Text] [PDF]


Home page
J. Neurophysiol.Home page
K. E. Jones, A. F. d. C. Hamilton, and D. M. Wolpert
Sources of Signal-Dependent Noise During Isometric Force Production
J Neurophysiol, September 1, 2002; 88(3): 1533 - 1544.
[Abstract] [Full Text] [PDF]


Home page
J. Neurophysiol.Home page
L. Griffin, S. Godfrey, and C. K. Thomas
Stimulation Pattern That Maximizes Force in Paralyzed and Control Whole Thenar Muscles
J Neurophysiol, May 1, 2002; 87(5): 2271 - 2278.
[Abstract] [Full Text] [PDF]


Home page
Physiol. Rev.Home page
S. C. Gandevia
Spinal and Supraspinal Factors in Human Muscle Fatigue
Physiol Rev, October 1, 2001; 81(4): 1725 - 1789.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
F. Borrani, R. Candau, G. Y. Millet, S. Perrey, J. Fuchslocher, and J. D. Rouillon
Is the {V}O2 slow component dependent on progressive recruitment of fast-twitch fibers in trained runners?
J Appl Physiol, June 1, 2001; 90(6): 2212 - 2220.
[Abstract] [Full Text] [PDF]


Home page
Physiol. Rev.Home page
O. M. Sejersted and G. Sjogaard
Dynamics and Consequences of Potassium Shifts in Skeletal Muscle and Heart During Exercise
Physiol Rev, October 1, 2000; 80(4): 1411 - 1481.
[Abstract] [Full Text] [PDF]


Home page
J. Physiol.Home page
V. G Macefield, A. J Fuglevand, J. N Howell, and B. Bigland-Ritchie
Discharge behaviour of single motor units during maximal voluntary contractions of a human toe extensor
J. Physiol., October 1, 2000; 528(1): 227 - 234.
[Abstract] [Full Text] [PDF]


Home page
J. Physiol.Home page
P A McNulty, K J Falland, and V G Macefield
Comparison of contractile properties of single motor units in human intrinsic and extrinsic finger muscles
J. Physiol., July 15, 2000; 526(2): 445 - 456.
[Abstract] [Full Text] [PDF]


Home page
J. Neurophysiol.Home page
C. K. Thomas, R. S. Johansson, and B. Bigland-Ritchie
Pattern of Pulses That Maximize Force Output From Single Human Thenar Motor Units
J Neurophysiol, December 1, 1999; 82(6): 3188 - 3195.
[Abstract] [Full Text] [PDF]


Home page
J. Neurophysiol.Home page
A. J. Fuglevand, V. G. Macefield, and B. Bigland-Ritchie
Force-Frequency and Fatigue Properties of Motor Units in Muscles That Control Digits of the Human Hand
J Neurophysiol, April 1, 1999; 81(4): 1718 - 1729.
[Abstract] [Full Text] [PDF]


Home page
J. Neurophysiol.Home page
S. A. Binder-Macleod, S. C. K. Lee, A. D. Fritz, and L. J. Kucharski
New Look at Force-Frequency Relationship of Human Skeletal Muscle: Effects of Fatigue
J Neurophysiol, April 1, 1998; 79(4): 1858 - 1868.
[Abstract] [Full Text] [PDF]


Home page
J. Neurophysiol.Home page
J. H. Mateika, E. G. Essif, C. Dellorusso, and R. F. Fregosi
Contractile Properties of Human Nasal Dilator Motor Units
J Neurophysiol, January 1, 1998; 79(1): 371 - 378.
[Abstract] [Full Text] [PDF]


Home page
NeuroscientistHome page
A. J. Fuglevand
Neural Aspects of Fatigue
Neuroscientist, July 1, 1996; 2(4): 203 - 206.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online