|
|
||||||||
INNOVATIVE METHODOLOGY
1Department of Neurobiology, Harvard Medical School, Boston, Massachusetts 02115; and 2Invitrogen, Corporation, Eugene, Oregon 97402
Submitted 16 January 2004; accepted in final form 26 February 2004
| ABSTRACT |
|---|
|
|
|---|
| INTRODUCTION |
|---|
|
|
|---|
Anecdotal reports suggest that the methods widely employed to measure Capre at room temperature are not readily applied at elevated temperatures. For room temperature studies, the preferred approach is to measure Capre with fluorescent 1,2-bis-(2-aminophenoxy)-N,N,N',N'-tetraacetic acid (BAPTA) derivatives of small molecular weight (Tsien 1980
). In contrast to green fluorescent protein (GFP)-based indicators that are slow and nonlinear (Higashijima et al. 2003
; Ikeda et al. 2003
; Miyawaki 2003
; Miyawaki et al. 1999
; Miyawaki et al. 1997
), these indicators have rapid kinetics, they can provide a linear measure of Capre, and they are available with a range of optical properties and calcium sensitivities. The acid form of these fluorophores can be loaded directly into cells with a pipette (Eilers and Konnerth 2000
). Alternatively they can be derivatized with acetoxymethyl (AM) esters to make them membrane-permeant (Tsien 1981
). Once inside cells, hydrolysis by intracellular esterases releases the ion-sensitive indicator. Although these indicators have been used to measure calcium transients within cell bodies at physiological temperatures (Stosiek et al. 2003
), measurements of Capre have been much more limited under these conditions. It is possible that these indicators, whether loaded as an acid or AM form, are pumped from cells at a rapid rate at high temperatures (Di Virgilio et al. 1990
; Roe et al. 1990
; Tombal et al. 1999
).
In addition, Capre can be measured with indicators conjugated to dextrans, which are long-chain polysaccharides of high molecular weight. Dextran dyes are not broken down by intracellular enzymes and are not extruded from the cytoplasm (Haugland 1996
). Therefore this class of indicators has been widely used for loading cell bodies or synapses in vivo (Edwards and Cline 1999
; Fetcho and O'Malley 1997
; Kreitzer et al. 2000
; McPherson et al. 1997
; O'Donovan et al. 1993
; Takahashi et al. 2002
; Wachowiak and Cohen 2001
) where large distances between the loading site and presynaptic terminals necessitate transport times of up to several days. Although there is currently a somewhat limited range of commercially available dextran-conjugated calcium indicators, their properties appear particularly promising for measurements of Capre at physiological temperatures.
Here we directly compared AM and dextran-conjugated indicators in their ability to report stable measurements of Capre at physiological temperatures. We found that under those conditions only dextran-conjugated indicators permit long-term measurements of Capre. To address the limitations in the properties of available dextran-conjugated dyes, we synthesized three new red indicators with a range of calcium affinities that are excited at wavelengths of 540580 nm. These dyes can be used at excitation and emission wavelengths that do notconflict with other dextran-conjugated calcium indicators or with GFP and are ideally suited for measurements where tissue autofluorescence is particularly problematic. Moreover we show that they are well suited to the measurement of Capre from individual synaptic terminals.
| METHODS |
|---|
|
|
|---|
Rats (P17P19) were anesthetized with halothane and decapitated, and transverse cerebellar slices (300 µm) were obtained as described previously (Atluri and Regehr 1996
). Slices were cut in a sucrose solution consisting of (in mM) 81.2 NaCl, 23.4 NaHCO3, 69.9 sucrose, 23.3 glucose, 2.4 KCl, 1.4 NaH2PO4, 6.7 MgCl2, and 0.5 CaCl2. Slices were incubated at 32°C for 30 min and then transferred to a saline solution for 30 min at 32°C consisting of (in mM) 125 NaCl, 26 NaHCO3, 2.5 KCl, 1.25 NaH2PO4, 25 glucose, 2 CaCl2, and 1 MgCl2. Experiments were performed at either 22 or 3536°C using an inline heater (Warner, Hamden, CT) while perfusing the bath with saline solution at 34 ml/min using a Minipulse 3 pump (Gilson, Middleton, WI). Parallel fibers were focally labeled with dextran-conjugated dyes using a high pressure stream, as previously described (Kreitzer et al. 2000
). The loading solution consisted of 0.2-0.8% dextran-conjugated dye, 0.1% Triton X-100, and 0.1% fast green in dH20. At present little is known about how hydrophilic dextran-conjugated dyes are taken up into axons. Triton X-100 may facilitate dye uptake by locally permeabilizing the membrane. Other mechanisms such as endo- or pinocytosis might also play a role.
Loading times were 1-2 min for high-affinity dextran dyes and 34 min for the low-affinity dextran dye. Slices were then incubated at 34°C for 23 h to ensure that dye was transported to near steady-state levels (see RESULTS). Due to the more extensive spread of dye along the fiber tract at elevated temperatures, dye concentrations were increased by a factor of 2 to 3 as compared with a previous study (Kreitzer et al. 2000
) to ensure high enough dye concentrations at steady-state. AM dyes were loaded into parallel fibers as described previously (Regehr 2000
), with loading times of 5-8 min. Slices were then incubated for 23 h at room temperature.
Optical imaging
Parallel fiber tracts were stimulated extracellularly, and epifluorescence was measured with a photomultiplier tube (H7422-40, Hamamatsu Photonics, Hamamatsu City, Japan) from a small area 400-700 µm from the loading site. Excitation was generated with a monochromator (Polychrome IV, Till Photonics, Gräfelfing, Germany). The excitation wavelength for magnesium green and calcium green dextran was 470 nm. The filter set used was 510DRLP dichroic, and 535DF35 for emission. The excitation wavelength used for the dyes rhod dextran (high and low affinity) was 540 nm, and the filter set was 560DRLP dichroic and 595AF60. The excitation wavelength for Texas Red and x-rhod dextran was 570 nm and the filter set was 590DRLP dichroic, and 600ALP for emission. The excitation wavelength for mag fura-5 AM was 370 nm and the filter set was 400 DRLP dichroic, and 525AF45 for emission (Omega Optical, Brattleboro, VT).
Time-lapse image sequences of dye-loaded parallel fiber bands were acquired using a 4x (0.28 NA) dry objective (Olympus, Tokyo) and a SensiCam CCD camera (PCO Computer Optics, Kelheim, Germany). Exposures ranged from 200 to 400 ms.
Imaging individual mossy fiber boutons
Parasagittal cerebellar slices (250 µm) of transgenic mice (P20P25) expressing GFP in cerebellar mossy fibers (Feng et al. 2000
) were prepared (Regehr and Mintz 1994
) and incubated as described in the preceding text. Mossy fibers were labeled with Texas Red dextran by focal application to white matter tracts. Two-photon laser-scanning images of mossy fiber boutons were obtained with a modified Olympus confocal microscope equipped with a Ti-sapphire pulsed laser (Coherent Laser Group, Santa Clara, CA). GFP and Texas Red dextran were simultaneously excited at 810 nm and image stacks were collected using Fluoview software (Olympus, Melville, NY).
For calcium measurements of individual synaptic boutons, mossy fibers were loaded with x-rhod dextran as described in the preceding text. To facilitate visualization, we included Texas Red dextran in the loading solution. Presynaptic mossy fibers were activated using glass electrodes (510 µm diam) placed in the granule cell layer. Calcium transients were measured at room temperature with a photomultiplier tube as described in the preceding text. Excitation was restricted to a single labeled bouton.
Data acquisition and analysis
All signals were digitized with a 16-bit A/D converter (ITC-16, Instrutech, Port Washington, NY). PMT currents were digitized at 20 kHz and digitally filtered at 400 Hz. All analysis was performed using custom macros written in Igor Pro (Wavemetrics, Lake Oswego, OR) or Vision Software (Till Photonics). Averages are given as means ± SE.
Synthesis of dextran-conjugated indicators
The synthesis involved condensation of two equivalents of 3-dimethylaminophenol (to generate the rhod dextrans) or 8-hydroxyjulolidine (to generate x-rhod dextran) with the BAPTA aldehyde (Fig. 1). The resulting dihydrorhodamines were oxidized with chloranil, then trifluoroacetic acid (TFA) was used to selectively remove the benzhydryl ester. The resultant carboxylic acid was activated as its N-hydroxy-succinimide ester, followed by reaction with 10,000 MW aminodextran. Finally, the BAPTA methyl esters were cleaved by saponification with KOH.
|
|
| RESULTS |
|---|
|
|
|---|
AM indicators have been widely used to measure Capre at room temperature (2025°C) or moderate temperatures (3032°C) at a variety of synapses in mammalian brain (Atluri and Regehr 1996
; Dittman and Regehr 1996
; Mintz et al. 1995
; Regehr et al. 1994
; Sabatini and Regehr 1996
-
1998
; Wu and Saggau 1994
). Here we tested whether they are also appropriate for long-term measurements of Capre at physiological temperatures of 3536°C. We first assessed whether AM indicators are retained in axons and presynaptic terminals by performing time-lapse measurements of fluorescence intensity in cerebellar parallel fiber tracts. For these experiments, we used mag fura-5 AM (Zhao et al. 1997
), a low-affinity calcium indicator with high fluorescence levels in the absence of calcium. Parallel fibers were loaded at 22°C and measurements commenced immediately after loading (Fig. 2A ). Plots of the fluorescence intensity as a function of either distance from the loading site (Fig. 2B) or time (C and D) show that mag fura-5 rapidly loaded parallel fibers. At distances of 600 and 900 µm from the loading site, peak fluorescence levels were reached 40 and 55 min after loading, respectively (n = 4). After 2 h, bath temperature was then increased to 35°C. This caused a rapid loss of fluorescence along the loaded parallel fiber tract (Fig. 2, A and C). On average fluorescence decreased with a half decay time of 23 ± 2 min (n = 5). Comparable results were obtained even when light exposure was reduced by a factor of 100, indicating that the fluorescence decrease reflected dye extrusion rather than photobleaching (n = 4, not shown). Fluorescence decreases with comparable half decay times were observed using magnesium green AM (n = 5, not shown). In contrast, when the preparation was maintained at 22°C for 4 h there was only a modest loss in fluorescence intensity over time (Fig. 2D).
|
Indicators conjugated to high-molecular-weight dextrans are less susceptible to extrusion (Glover et al. 1986
; Haugland 1996
) and thus may be a viable alternative for measuring Capre at physiological temperatures. We therefore performed time-lapse imaging experiments with Texas Red dextran to assess the transport and retention of dextran dyes within presynaptic terminals (Fig. 3, AC). At room temperature, Texas Red dextran was transported much more slowly within parallel fibers than were AM indicators. At 22°C, peak fluorescence levels at distances of 600 µm from the loading site were reached only after 46 h (Fig. 3D, cf. Fig. 2D), and sites more distal did not reach steady-state levels after 6 h. In separate experiments when the bath temperature was raised to 35°C after 2 h, redistribution of the dye along the fiber tract occurred with a faster time course that led to a smaller fluorescence gradient between sites proximal and distal to the loading site compared with incubation at room temperature (Fig. 3C, cf. Fig. 3D). Furthermore there was little evidence for dye extrusion. Similar results were obtained with calcium green dextran (n = 4, data not shown). These data suggest that dextran-conjugated dyes are not extruded from parallel fibers and travel in axons via active, temperature-dependent transport.
|
The data in Fig. 2 indicate that AM dyes are rapidly extruded from the axons of parallel fibers. To more directly relate dye extrusion to the measurement of Capre we measured fluorescence transients generated by the low-affinity calcium indicator magnesium green AM (Fig. 4A). Parallel fiber tracts were loaded and slices were incubated for 23 h at room temperature prior to imaging. We then measured fluorescence transients evoked by single stimuli to parallel fibers once every min. At 22°C, fluorescence intensity decreased slightly while the amplitude of the fluorescence transients remained stable (Fig. 4A, left). On average, fluorescence levels decayed to 89 ± 2% (n = 3) after 120 min. Amplitudes of fluorescence transients at 120 min remained virtually unchanged (101 ± 4%). In a different set of experiments, we raised the bath temperature to 35°C after 30 min. This led to an initial increase in fluorescence intensity (Fig. 4A, right). It is likely that this increase reflected increased binding of magnesium to the indicator as magnesium levels are the main determinant of magnesium green fluorescence under resting conditions (Haugland 1996
). After this initial increase fluorescence levels then gradually declined. On average, fluorescence intensities 30 min after raising the bath temperature were 81 ± 4% of control, 30 ± 4% after 60 min, and 10 ± 3% after 90 min (n = 10) compared with fluorescence intensity levels prior to the increase in temperature. The amplitude of the fluorescence transient immediately decreased to 39 ± 4% of control, after the increase in bath temperature. This decrease likely reflected a reduction in calcium influx due to changes in presynaptic waveform and faster calcium channel kinetics at higher temperatures (Sabatini and Regehr 1996
, 1999
). Fluorescent transients remained relatively constant for
30 min and then began to decrease further. After
90 min fluorescence transients could no longer be evoked (inset, Fig. 4A, right). On average, peaks were 96 ± 3% after 30 min, 49 ± 3% after 60 min, and 13 ± 2% after 90 min compared with the values immediately after the temperature increase. Thus while calcium transients remained stable for
30 min in spite of significant dye loss, long-term measurements were not feasible with AM indicators.
|
3 h at 35°C before performing calcium measurements. To improve our ability to keep dye concentrations relatively constant over the course of the experiment, measurements were performed 500700 µm from the loading site where relative changes in dye concentrations were minimal after 3 h (cf. Fig. 3, B and C). When measurements were performed at room temperature, both fluorescence intensity (n = 4) and calcium transients remained stable over 120 min (Fig. 4B, left). On average, fluorescence levels after 120 min were 96 ± 1%, and the amplitudes of calcium transients were 104 ± 3% (n = 4), compared with their respective values at the beginning of the measurements. Similarly, when recordings were made with the bath temperature held at 35°C for the entire duration of the experiment (Fig. 4B, right), neither fluorescence intensity nor the amplitudes of the calcium transient changed significantly. On average intensity values were 98 ± 6% and peak fluorescence transients 100 ± 3% (n = 4) after 120 min compared with their respective values at time 0. Taken together, our results indicate that AM dyes are extruded via a temperature-dependent mechanism and therefore do not permit long-term measurements of Capre. In contrast, dextran-conjugated dyes can be used to perform stable measurements of Capre, provided that the slow speed and temperature-dependence of dye redistribution within the loaded fiber system are taken into account.
Red dextran-conjugated calcium indicators
Although dextran-conjugated indicators appear suitable for measuring Capre, there are relatively few such indicators available. In particular, few indicators exist that are excited and fluoresce at longer wavelengths. Such indicators would be useful, for several reasons. First, tissue autofluorescence, which can interfere with identification of labeled presynaptic structures and with measurements of Capre, is less problematic for long wavelength excitation and emission. Second, it is often useful to have indicators with nonoverlapping emission to label multiple pathways converging onto the same target. Finally, it is desirable to measure calcium in GFP labeled neurons, but GFP fluorescence interferes with the measurements of Capre using most available dextran-conjugated calcium indicators.
We therefore synthesized three new dextran-conjugated calcium indicators (Fig. 5, Table 1) based on the fluorophore rhodamine. Both x-rhod dextran and rhod dextran (high affinity) have a relatively high affinity for calcium (KD = 1.4 µM). This was achieved by the separation of the BAPTA phenyl ring and the electron-withdrawing carbonyl group with a methylene group (Fig. 5, A and B, arrows), leaving intact the high calcium ion affinity of a normal BAPTA moeity. By contrast, for rhod dextran (low affinity) the carbonyl group that provides the aminodextran attachment site was directly bound to one of the BAPTA phenyl rings, lowering the calcium ion affinity by virtue of the electron withdrawing character of the carbonyl group (KD = 3.9 µM). X-rhod dextran and rhod dextran have the same chelator substitution pattern and dextran attachment but differ in the dye portion of the molecule that results in a red-shifted excitation and emission band.
|
F/F (Regehr and Atluri 1995
|
10 ms. High-affinity indicators do not accurately report the time course of Capre due to indicator saturation and slow off rates (Sabatini and Regehr 1998The responses of the three indicators to trains of stimuli also illustrate differences in their ability to track Capre during ongoing activity (Fig. 6, A, right, and C). For fluorescence signals mediated by rhod dextran (high affinity) and x-rhod dextran, 20-Hz trains slightly accentuated the amount of saturation (Fig. 6C). By contrast, for rhod dextran (low affinity), stimulus-evoked fluorescence increases remained similar throughout the train. These findings demonstrate that although rhod dextran (low affinity) can slightly distort the time course of calcium decay, it is well suited to quantifying calcium entry during moderate frequency trains in a manner that is similar to fluo-4 dextran.
Measuring calcium influx in single synaptic boutons
In addition to obtaining aggregate measurements from a population of synapses, as we did here for parallel fibers, it is often desirable to measure Capre from individual presynaptic boutons. To date most functional imaging studies of single synapses in brain slices require the direct filling of the presynaptic neuron with calcium fluorophores (Helmchen et al. 1997
; Koester and Sakmann 2000
). However, this approach is not feasible for the study of most synapses.
Alternatively, presynaptic boutons could be labeled by focally loading axons with dextran indicators. This approach could prove particularly promising in systems with GFP expression in distinct subsets of presynaptic axons (Feng et al. 2000
). However, focal loading of individual synaptic boutons with dextran indicators in brain slices has not been demonstrated. In addition, the excitation and emission spectra of GFP and its variants are broad and overlap with those of currently available dextran-conjugated indicators (Bolsover et al. 2001
).
We found that we could focally load Texas Red dextran into cerebellar mossy fibers of mice in which a small percentage of cerebellar mossy fibers express GFP (Feng et al. 2000
). Texas Red dextran has excitation and emission spectra similar to ones of the red indicators but is easier to visualize as all three calcium dependent indicators emit little fluorescence at resting calcium levels (Fig. 5D). As shown using 2-Photon laser scanning microscopy, loading with dextrans allows for detection of individual boutons against a low-noise background (Fig. 7A). Furthermore, mossy fibers expressing GFP were well separated from dye-loaded boutons (Fig. 7, B and C).
|
| DISCUSSION |
|---|
|
|
|---|
A major goal of our study was to determine what method is best suited to measuring Capre at physiological temperatures. We found that indicator extrusion was a major limitation for AM-based calcium indicators. Despite the relative stability of Capre measurements with AM indicators at room temperature, at physiological temperatures, these indicators were rapidly extruded from presynaptic fibers. Thus the use of AM indicators requires loading and equilibration at room temperature, before the temperature can be changed to physiological levels. However, in these experiments, indicator extrusion leads to first a degradation of the signal-to-noise ratio, followed by a complete loss of the signal. This places a practical limit on these types of experiments of 20 min to one hour. Additionally, loss of indicator during the experiment can alter the buffer capacity of the presynaptic terminal and lead to a perceived alteration in the time course and amplitude of the calcium transient. Moreover, as the indicator concentration decreases, the background correction becomes increasingly important and can affect the determination of
F/F.
Our findings contrast with a recent report of AM indicators being used to measure somatic calcium transients for several hours at physiological temperatures with only a moderate decrease in fluorescence intensity (Stosiek et al. 2003
). Although these differences are not well understood, it is likely that the much higher surface-to-volume ratio of parallel fibers relative to cell bodies contributes to the more pronounced extrusion within presynaptic structures. In a variety of neuronal and nonneuronal cell lines, dye extrusion is mediated by organic anion transport systems (Di Virgilio et al. 1990
). Differences in the expression of transporters could also contribute to the more pronounced extrusion of AM indicators from parallel fibers.
In contrast, dextran-conjugated indicators were retained inside parallel fibers and thus permit long-term measurements of Capre with only moderate changes in fluorescence intensity. The long-term stability of both calcium transients and fluorescence levels indicate that this class of dyes is not compartmentalized inside organelles. These results further show that calcium indicators in general are not chemically altered at higher temperatures. It is unlikely that dextran-conjugation of an indicator will influence its sensitivity to degradation. Therefore the fluorescence loss observed with AM-based indicators is most likely explained by active extrusion from the cytoplasm.
An important practical consideration in measuring Capre with dextran indicators is that they equilibrate within fibers very slowly at room temperature. The transport is greatly accelerated at physiological temperatures in a manner that suggests mechanisms other than simple diffusion. However, even at high temperatures it takes several hours for dye levels to distribute uniformly within the presynaptic structures. As a result, the most stable Capre measurements with dextrans involved incubating the slices for 2 h at 34°C before commencing Capre measurements.
Dextran dyes offer several advantages over AM indicators. Because they are retained inside fiber tracts for up to several days they can be loaded in vivo, thus permitting labeling of even distant targets (Edwards and Cline 1999
; Fetcho and O'Malley 1997
; Kreitzer et al. 2000
; McPherson et al. 1997
; O'Donovan et al. 1993
; Takahashi et al. 2002
; Wachowiak and Cohen, 2001
). Unlike AM dyes, dextran dyes can also be loaded into heavily myelinated fiber tracts such as the cerebellar white matter, the optic tract, or the thalamocortical pathway. Furthermore dextran dyes label only a small percentage of fibers (Fig. 7A), making it feasible to isolate individual dye-filled terminals without interference of other labeled structures. Here we have shown that red dextran dyes are particularly suitable for single bouton measurements by labeling mossy fibers in cerebellar slices. This approach could readily be applied to other synapses. In preliminary studies, we were able to load retinogeniculate axons in the optic tract and perform measurements from individual terminals in the lateral geniculate nucleus (LGN).
Red dextran dyes
The three red dextran-conjugated indicators we have introduced here promise to be useful in several ways. The existence of two low-affinity dyes with nonoverlapping emission spectra, fluo-4 dextran (Kreitzer et al. 2000
) and rhod dextran (low affinity), now enables experiments in which the presynaptic activity patterns from two distinct populations are faithfully monitored. For example, these dyes could be loaded into the optic tracts of both eyes in vivo to measure Capre in retinogeniculate terminals originating from ipsilateral and contralateral eye converging into the same target area in the LGN. Low-affinity indicators are particularly useful for quantitative studies where the time course of Capre is to be determined, changes in calcium influx are to be quantified, or Capre is to be quantified during trains. Higher-affinity indicators such as rhod dextran (high affinity) and x-rhod dextran are more appropriate for more qualitative studies requiring higher sensitivity. These red indicators can be used with the other high-affinity indicators fura-2 dextran and calcium green dextran to allow simultaneous measurement of calcium arising from three populations of presynaptic fibers. For example, in the LGN this could include corticothalamic synapses and retinogeniculate inputs from the ipsi- and contralateral retina.
One attractive feature of the red indicators is in applications where the tissue has high levels of autofluorescence for excitation in the 340- to 490-nm range. There is often much less tissue fluorescence for excitation of 550600 nm. Although we have focused on the measurement of Capre, red dextrans will be more generally useful for recording from neurons. The ability to measure calcium transients in cells in a manner that is compatible with GFP is particularly attractive and will become increasingly important with the more widespread use of GFP-labeling to guide measurements from specific types of neurons or synapses.
| GRANTS |
|---|
|
|
|---|
| ACKNOWLEDGMENTS |
|---|
|
|
|---|
| FOOTNOTES |
|---|
Address for reprint requests and other correspondence: W. G. Regehr, Dept. of Neurobiology, Harvard Medical School, 220 Longwood Ave., Boston MA 02115 (E-mail: wade_regehr{at}hms.harvard.edu).
| REFERENCES |
|---|
|
|
|---|
Bolsover S, Ibrahim O, O'Luanaigh N, Williams H, and Cockcroft S. Use of fluorescent Ca2+ dyes with green fluorescent protein and its variants: problems and solutions. Biochem J 356: 345352, 2001.[CrossRef][ISI][Medline]
Di Virgilio F, Steinberg TH, and Silverstein SC. Inhibition of Fura-2 sequestration and secretion with organic anion transport blockers. Cell Calcium 11: 5762, 1990.[CrossRef][ISI][Medline]
Dittman JS and Regehr WG. Contributions of calcium-dependent and calcium-independent mechanisms to presynaptic inhibition at a cerebellar synapse. J Neurosci 16: 16231633, 1996.
Edmonds B, Reyes R, Schwaller B, and Roberts WM. Calretinin modifies presynaptic calcium signaling in frog saccular hair cells. Nat Neurosci 3: 786790, 2000.[CrossRef][ISI][Medline]
Edwards JA and Cline HT. Light-induced calcium influx into retinal axons is regulated by presynaptic nicotinic acetylcholine receptor activity in vivo. J Neurophysiol 81: 895907, 1999.
Eilers J and Konnerth A. Dye Loading with Patch Pipets. In: Imaging Neurons: A Laboratory Manual, edited by Yuste R, Lanni F, and Konnerth A. New York: Cold Spring Harbor Laboratory Press, 2000, p. 35.31-35.10.
Feng G, Mellor RH, Bernstein M, Keller-Peck C, Nguyen QT, Wallace M, Nerbonne JM, Lichtman JW, and Sanes JR. Imaging neuronal subsets in transgenic mice expressing multiple spectral variants of GFP. Neuron 28: 4151, 2000.[CrossRef][ISI][Medline]
Fetcho JR and O'Malley DM. Imaging neuronal networks in behaving animals. Curr Opin Neurobiol 7: 832838, 1997.[CrossRef][ISI][Medline]
Glover JC, Petursdottir G, and Jansen JK. Fluorescent dextran-amines used as axonal tracers in the nervous system of the chicken embryo. J Neurosci Methods 18: 243254, 1986.[CrossRef][ISI][Medline]
Haugland RP. Handbook of Fluorescent Probes and Research Chemicals. Eugene, OR: Molecular Probes, 1996.
Helmchen F, Borst JG, and Sakmann B. Calcium dynamics associated with a single action potential in a CNS presynaptic terminal. Biophys J 72: 14581471, 1997.
Higashijima S, Masino MA, Mandel G, and Fetcho JR. Imaging neuronal activity during zebrafish behavior with a genetically encoded calcium indicator. J Neurophysiol 90: 39863997, 2003.
Ikeda M, Sugiyama T, Wallace CS, Gompf HS, Yoshioka T, Miyawaki A, and Allen CN. Circadian dynamics of cytosolic and nuclear Ca2+ in single suprachiasmatic nucleus neurons. Neuron 38: 253263, 2003.[CrossRef][ISI][Medline]
Koester HJ and Sakmann B. Calcium dynamics associated with action potentials in single nerve terminals of pyramidal cells in layer 2/3 of the young rat neocortex. J Physiol 529: 625646, 2000.
Kreitzer AC, Gee KR, Archer EA, and Regehr WG. Monitoring presynaptic calcium dynamics in projection fibers by in vivo loading of a novel calcium indicator. Neuron 27: 2532, 2000.[CrossRef][ISI][Medline]
McAllister-Williams RH and Kelly JS. The temperature dependence of high-threshold calcium channel currents recorded from adult rat dorsal raphe neurons. Neuropharmacology 34: 14791490, 1995.[CrossRef][ISI][Medline]
McPherson D, McClellan A, and O'Donovan M. Optical imaging of neuronal activity in tissue labeled by retrograde transport of calcium green dextran. Brain Res Protocols 1: 157164, 1997.[CrossRef][Medline]
Mintz IM, Sabatini BL, and Regehr WG. Calcium control of transmitter release at a cerebellar synapse. Neuron 15: 675688, 1995.[CrossRef][ISI][Medline]
Miyawaki A. Fluorescence imaging of physiological activity in complex systems using GFP-based probes. Curr Opin Neurobiol 13: 591596, 2003.[CrossRef][ISI][Medline]
Miyawaki A, Griesbeck O, Heim R, and Tsien RY. Dynamic and quantitative Ca2+ measurements using improved cameleons. Proc Natl Acad Sci USA 96: 21352140, 1999.
Miyawaki A, Llopis J, Heim R, McCaffery JM, Adams JA, Ikura M, and Tsien RY. Fluorescent indicators for Ca2+ based on green fluorescent proteins and calmodulin. Nature 388: 882887, 1997.[CrossRef][Medline]
Nobile M, Carbone E, Lux HD, and Zucker H. Temperature sensitivity of Ca currents in chick sensory neurons. Pfluegers 415: 658663, 1990.
O'Donovan MJ, Ho S, Sholomenko G, and Yee W. Real-time imaging of neurons retrogradely and anterogradely labeled with calcium-sensitive dyes. J Neurosci Methods 46: 91106, 1993.[CrossRef][ISI][Medline]
Regehr WG. Monitoring presynaptic calcium dynamics with membrane-permeant indicators. In: Imaging Neurons: A Laboratory Manual, edited by Yuste R, Lanni F, and Konnerth A. New York: Cold Spring Harbor Laboratory Press, 2000, p. 37.31-37.11.
Regehr WG and Atluri PP. Calcium transients in cerebellar granule cell presynaptic terminals. Biophys J 68: 21562170, 1995.
Regehr WG, Delaney KR, and Tank DW. The role of presynaptic calcium in short-term enhancement at the hippocampal mossy fiber synapse. J Neurosci 14: 523537, 1994.[Abstract]
Regehr WG and Mintz IM. Participation of multiple calcium channel types in transmission at single climbing fiber to Purkinje cell synapses. Neuron 12: 605613, 1994.[CrossRef][ISI][Medline]
Roe MW, Lemasters JJ, and Herman B. Assessment of Fura-2 for measurements of cytosolic free calcium. Cell Calcium 11: 6373, 1990.[CrossRef][ISI][Medline]
Sabatini BL and Regehr WG. Timing of neurotransmission at fast synapses in the mammalian brain. Nature 384: 170172, 1996.[CrossRef][Medline]
Sabatini BL and Regehr WG. Control of neurotransmitter release by presynaptic waveform at the granule cell to Purkinje cell synapse. J Neurosci 17: 34253435, 1997.
Sabatini BL and Regehr WG. Optical detection of presynaptic calcium currents. Biophys J 74: 15491563, 1998.
Sabatini BL and Regehr WG. Timing of synaptic transmission. Annu Rev Physiol 61: 521542, 1999.[CrossRef][ISI][Medline]
Stosiek C, Garaschuk O, Holthoff K, and Konnerth A. In vivo two-photon calcium imaging of neuronal networks. Proc Natl Acad Sci USA 100: 73197324, 2003.
Takahashi M, Narushima M, and Oda Y. In vivo imaging of functional inhibitory networks on the mauthner cell of larval zebrafish. J Neurosci 22: 39293938, 2002.
Tombal B, Denmeade SR, and Isaacs JT. Assessment and validation of a microinjection method for kinetic analysis of [Ca2+]i in individual cells undergoing apoptosis. Cell Calcium 25: 1928, 1999.[CrossRef][ISI][Medline]
Tsien R and Pozzan T. Measurement of cytosolic free Ca2+ with quin2. Methods Enzymol 172: 230262, 1989.[ISI][Medline]
Tsien RY. New calcium indicators and buffers with high selectivity against magnesium and protons: design, synthesis, and properties of prototype structures. Biochemistry 19: 23962404, 1980.[CrossRef][Medline]
Tsien RY. A non-disruptive technique for loading calcium buffers and indicators into cells. Nature 290: 527528, 1981.[CrossRef][Medline]
Wachowiak M and Cohen LB. Representation of odorants by receptor neuron input to the mouse olfactory bulb. Neuron 32: 723735, 2001.[CrossRef][ISI][Medline]
Wu L-G and Saggau P. Adenosine inhibits evoked synaptic transmission primarily by reducing presynaptic calcium influx in area CA1 of hippocampus. Neuron 12: 11391148, 1994.[CrossRef][ISI][Medline]
Zenisek D and Matthews G. The role of mitochondria in presynaptic calcium handling at a ribbon synapse. Neuron 25: 229237, 2000.[CrossRef][ISI][Medline]
Zhao M, Hollingworth S, and Baylor SM. AM-loading of fluorescent Ca2+ indicators into intact single fibers of frog muscle. Biophys J 72: 27362747, 1997.
Zucker RS and Regehr WG. Short-term synaptic plasticity. Annu Rev Physiol 64: 355405, 2002.[CrossRef][ISI][Medline]
This article has been cited by other articles:
![]() |
S. D. Brenowitz and W. G. Regehr Reliability and Heterogeneity of Calcium Signaling at Single Presynaptic Boutons of Cerebellar Granule Cells J. Neurosci., July 25, 2007; 27(30): 7888 - 7898. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. M. Empson, M. L. Garside, and T. Knopfel Plasma Membrane Ca2+ ATPase 2 Contributes to Short-Term Synapse Plasticity at the Parallel Fiber to Purkinje Neuron Synapse J. Neurosci., April 4, 2007; 27(14): 3753 - 3758. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Wachowiak, J. P. McGann, P. M. Heyward, Z. Shao, A. C. Puche, and M. T. Shipley Inhibition of Olfactory Receptor Neuron Input to Olfactory Bulb Glomeruli Mediated by Suppression of Presynaptic Calcium Influx J Neurophysiol, October 1, 2005; 94(4): 2700 - 2712. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||