JN Miami Valley Hospital
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


J Neurophysiol (September 27, 2006). doi:10.1152/jn.00679.2006
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
97/1/912    most recent
00679.2006v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ganesh, G
Right arrow Articles by Kawato, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ganesh, G
Right arrow Articles by Kawato, M.
Submitted on June 30, 2006
Accepted on September 24, 2006

Accurate Real-time Feedback of Surface EMG during fMRI

G Ganesh1*, David W Franklin1, Roger Gassert2, Hiroshi Imamizu3, and Mitsuo Kawato3

1 NICT, JAPAN, Kyoto, Kyoto, Japan
2 LSRO, EPFL, Lausanne, Switzerland
3 Kyoto, Kyoto, Japan; CNS, ATR, Kyoto, Kyoto, Japan

* To whom correspondence should be addressed. E-mail: gganesh{at}atr.jp.

Real-time acquisition of electromyography (EMG) during functional Magnetic Resonance Imaging (fMRI) provides a novel method of controlling motor experiments in the scanner using feedback of EMG. Due to the redundancy in the human muscle system this is not possible from recordings of joint torque and kinematics alone, as these provide no information about individual muscle activation. This is particularly critical during brain imaging as brain activations are not only related to joint torques and kinematics but are also related to individual muscle activation. However, EMG collected during imaging is corrupted by large artifacts induced by the varying magnetic fields and radio-frequency (RF) pulses in the scanner. Methods proposed in literature for artifact removal are complex, computationally expensive and difficult to implement for real-time noise removal. We describe an acquisition system and algorithm which enables real-time acquisition for the first time. The algorithm removes particular frequencies from the EMG spectrum in which the noise is concentrated. Although this decreases the power content of the EMG, this method provides excellent estimates of EMG with good resolution. Comparisons show that the cleaned EMG obtained with the algorithm is, like actual EMG, very well correlated with joint torque and can thus be used for real-time visual feedback during functional studies.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
Visit Other APS Journals Online
Copyright © 2006 by the The American Physiological Society.