JN Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


J Neurophysiol (November 17, 2004). doi:10.1152/jn.01023.2004
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
93/5/2987    most recent
01023.2004v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Blanche, T. J.
Right arrow Articles by Swindale, N. V.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Blanche, T. J.
Right arrow Articles by Swindale, N. V.
Submitted on September 28, 2004
Accepted on November 14, 2004

Polytrodes: High Density Silicon Electrode Arrays for Large Scale Multiunit Recording

Timothy J. Blanche, Martin A. Spacek, Jamille F. Hetke, and Nicholas V. Swindale*

* To whom correspondence should be addressed. E-mail: swindale{at}interchange.ubc.ca.

We developed a variety of 54-channel high density silicon electrode arrays (polytrodes) designed to record from large numbers of neurons spanning millimeters of brain. In cat visual cortex it was possible to make simultaneous recordings from more than 100 well-isolated neurons. Using standard clustering methods, polytrodes provide a quality of single-unit isolation that surpasses that attainable with tetrodes. Guidelines for successful in vivo recording and precise electrode positioning are described. We also describe a high-bandwidth continuous data acquisition system designed specifically for polytrodes, and an automated impedance meter for testing polytrode site integrity. Despite having smaller interconnect pitches than earlier silicon-based electrodes of this type, these polytrodes have negligible channel crosstalk, comparable reliability, low site impedances, and are capable of making high fidelity multiunit recordings with minimal tissue damage. The relatively benign nature of planar electrode arrays is evident both histologically and in experiments where the polytrode was repeatedly advanced and retracted hundreds of microns over periods of many hours. It was possible to maintain stable recordings from active neurons adjacent to the polytrode without change in their absolute positions, neurophysiological or receptive field properties.




This article has been cited by other articles:


Home page
J. Neurophysiol.Home page
S.-C. Yen, J. Baker, and C. M. Gray
Heterogeneity in the Responses of Adjacent Neurons to Natural Stimuli in Cat Striate Cortex
J Neurophysiol, February 1, 2007; 97(2): 1326 - 1341.
[Abstract] [Full Text] [PDF]


Home page
J. Neurosci.Home page
P. J. Magill, A. Pogosyan, A. Sharott, J. Csicsvari, J. P. Bolam, and P. Brown
Changes in functional connectivity within the rat striatopallidal axis during global brain activation in vivo.
J. Neurosci., June 7, 2006; 26(23): 6318 - 6329.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
Visit Other APS Journals Online
Copyright © 2004 by the The American Physiological Society.