JN Ad Instruments
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


J Neurophysiol (December 24, 2008). doi:10.1152/jn.90989.2008
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
101/3/1679    most recent
90989.2008v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Web of Science (2)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ludwig, K. A
Right arrow Articles by Kipke, D. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ludwig, K. A
Right arrow Articles by Kipke, D. R.
Submitted on September 3, 2008
Revised on December 15, 2008
Accepted on December 15, 2008

Employing a Common Average Reference to Improve Cortical Neuron Recordings from Microelectrode Arrays

Kip A Ludwig1*, Rachel Miriani1, Nicholas B Langhals1, Michael D Joseph1, David J. Anderson, and Daryl Richard Kipke

1 University of Michigan

* To whom correspondence should be addressed. E-mail: ludwigk{at}umich.edu.

In this study, we propose and evaluate a technique known as common average referencing (CAR) to generate a more ideal reference electrode for microelectrode recordings. CAR is a computationally simple technique, and therefore amenable to both on-chip and real-time applications. CAR is commonly employed in electroencephalography (EEG), where it is necessary to identify small signal sources in very noisy recordings. In order to investigate the efficacy of common average referencing, we compared CAR to both referencing with a stainless steel bone-screw, and a single microelectrode site. Data consisted of in vivo chronic recordings in anesthetized Sprague Dawley rats drawn from prior studies, as well as previously unpublished data. By combining the data from multiple studies, we have generated and analyzed one of the more comprehensive chronic neural recording datasets to date. Reference types were compared in terms of noise level, signal-to-noise ratio, and number of neurons recorded across days. Common average referencing was found to drastically outperform standard types of electrical referencing, reducing noise by more than 30 percent. As a result of the reduced noise floor, arrays referenced to a CAR yielded almost 60 percent more discernible neural units than traditional methods of electrical referencing. CAR should impart similar benefits to other microelectrode recording technologies - for example, chemical sensing - where similar differential recording concepts apply. In addition, we provide a mathematical justification for CAR using Gauss-Markov theorem, and therefore help place the application of CAR into a theoretical context. Keywords: Microelectrode array, chronic neural recordings, ground, common average reference







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
Visit Other APS Journals Online
Copyright © 2008 by the The American Physiological Society.