JN Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


J Neurophysiol (December 17, 2008). doi:10.1152/jn.90992.2008
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
101/3/1671    most recent
90992.2008v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Web of Science (3)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Du, J.
Right arrow Articles by Masmanidis, S. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Du, J.
Right arrow Articles by Masmanidis, S. C.
Submitted on September 3, 2008
Revised on October 4, 2008
Accepted on December 12, 2008

High-Resolution Three-Dimensional Extracellular Recording of Neuronal Activity with Microfabricated Electrode Arrays

Jiangang Du1, Ingmar H. Riedel-Kruse1, Janna C. Nawroth1, Michael L. Roukes1, Gilles J. Laurent1, and Sotiris C. Masmanidis2*

1 California Institute of Technology
2 California Institute of Technolog

* To whom correspondence should be addressed. E-mail: sotiris{at}caltech.edu.

Microelectrode array recordings of neuronal activity present significant opportunities for studying the brain with single cell and spike time precision. However, challenges in device manufacturing constrain dense multisite recordings to two spatial dimensions, whereas access to the three-dimensional (3D) structure of many brain regions appears to remain a challenge. To overcome this limitation, we present two novel recording modalities of silicon-based devices aimed at establishing 3D functionality. First, we fabricated a dual-side electrode array by patterning recording sites on both the front and back of an implantable microstructure. We found that the majority of single-unit spikes could not be simultaneously detected from both sides, suggesting that in addition to providing higher spatial resolution measurements than single-side devices, dual-side arrays also lead to increased recording yield. Second, we obtained recordings along three principal directions with a multilayer array and demonstrated 3D spike source localization within the enclosed measurement space. The large scale integration of such dual-side and multilayer arrays is expected to provide massively parallel recording capabilities in the brain.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
Visit Other APS Journals Online
Copyright © 2008 by the The American Physiological Society.